فروشگاه

Fire Detection Control Panel BC600-16L2S – 211240

The Fire Detection Control Panel BC06-1/INT1 is a compact control panel for small conventional fire detection systems. Depending on the level of expansion, fire detectors, fault detectors and condition detectors can be connected to a maximum of 6 conventional detector lines. Outputs for two alarming devices are provided as well. The control panel was tested by VdS, according to the construction Products Directive CPD, for compliance according to the European Standards EN 54-2 and EN 54-4

The control panel is integrated in a wall-mount cabinet. The cabinet consists of a powder coated steel sheet base and a removable plastic cabinet cover. In the basic version, the control panel contains 4 conventional detector zones, 2 parameterisable inputs, 2 independently monitored siren outputs and 2 relay outputs. The Fire Detection Control Panel Series BC06 can be extended to 6 detector zones by the installation of the Zone Extension Board ZEB2-1. In addition, the wall-mount cabinet can accommodate an optional componentry (Relay Module RL58-1 or RL58-2, Siren Connection Module SZ58-3, etc.) as well as stand-by batteries 2 × 12V/max. 7Ah. Enclosed with the control panel is a documentation in English language. The initial commissioning of the control panel is significantly facilitated by the practical factory settings. The system-specific parameterisation of the control panel can be directly accomplished via the keypad of the integrated display and operating field without the requirement of any additional support

Description

Administration of up to 6 detector zones for manual call points, automatic fire detectorswith or without alarm verification and fault detectors with or without self-resetting property

With the help of the optional MCP Coding Module MCM1-1, alarms from automatic detectors and manual call points, which are both connected to the same detector line, can be distinguished by the Fire Detection Control Panel Series BC06

The type of line terminator (end-of-line resistor or end-of-line capacitor) can be selected via parameterisation

Two monitored outputs for the connection of external alarming devices with the possibility of individual activation via ‘and/or’ combinations

Independent indication of activation, fault and disablement of the alarming devices as well as independent operation via one button per alarming device

Summary LED indicators for information about all current events

8 LED pairs are automatically assigned to parameterised zones and alarming devices and display the activation, disablement and fault condition

Displays can be labelled individually with labelling strips, which are inserted into the front foil

Event memory for the last 50 events in chronological order, to be output via the serial interface 2 dry contact outputs. These outputs are pre-set in the factory settings according to EN 54 standards (summary alarm and summary fault

8 open-collector outputs, that automatically signal the activated condition of each zone and one summary output each for fault condition and disabled condition of the zones

Button ‘Panel reset’ for common reset of all current events

3 authorisation levels for operation and parameterisation, secured by numeric codes

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Fire Detection Control Panel BC600-16L2S – 211240”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *